Bioresorbable Scaffold T-stenting Evaluated With Optical Coherence Tomography

Carlos Ortiz a,, Hipólito Gutiérrez a, José A. San Román a

a Servicio de Cardiología, Instituto de Ciencias del Corazón (ICICOR), Hospital Clínico Universitario de Valladolid, Valladolid, Spain

Article

A 69-year-old man without cardiovascular risk factors was admitted to our hospital with unstable angina. After 48 hours he underwent coronary angiography, showing severe disease of mid left anterior descending (LAD) coronary artery and proximal segment of the first diagonal (DX) (Figure 1A).

Figure 1.

Balloon predilation was performed in LAD and 2 bioresorbable everolimus-eluting (3 × 28 mm and 3.5 × 28 mm) overlapped scaffolds (Absorb, Abbott Vascular, Santa Clara, California, United States) were implanted in LAD, jailing the DX. The result at LAD was excellent but DX worsened to 90% stenosis with TIMI II flow (Figure 1B). Hence, “kissing-balloon” dilation was performed with a 3 × 15 mm balloon at LAD and 2.5 × 15 mm balloon at DX (Figure 1C). As the compromise of DX persisted, we implanted a bioresorbable everolimus-eluting scaffold (2.5 × 18 mm) through the proximal stent in a T-fashion stenting, inflating a 3 × 15 mm balloon in LAD to avoid scaffold protrusion, with excellent angiographic final result (Figure 1D). Several optical coherence tomography pullbacks from LAD and DX were performed, confirming correct strut apposition. There was a slight protrusion of the DX scaffold into LAD, perhaps because the balloon used to avoid scaffold protrusion was too small (Figure 2A: pullback from LAD and 2B: pullback from DX, *struts protruding from DX in LAD). Patient was discharged on dual antiplatelet therapy (acetylsalicylic acid, clopidogrel) for a year. Six months later remained asymptomatic.

Figure 2.

Although increasing, experience with bioresorbable scaffolds in some situations, such as bifurcations, is limited. This is, to the best of our knowledge, the first case in which a true T-stenting was performed using bioresorbable scaffolds.

Corresponding author: ortiz.bautista.carlos@gmail.com

1885-5857/© 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved

Cookies
x
To improve our services and products, we use cookies (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here.
Cookies policy
x
To improve our services and products, we use cookies (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here.