Culotte Technique With a Bioresorbable Vascular Scaffold: 12 Months’ Follow-up

Lucía Vera Pernasetti a,, Hipólito Gutiérrez a, Benigno Ramos a

a Servicio de Cardiología, Instituto de Ciencias del Corazón (ICICOR), Hospital Clínico Universitario de Valladolid, Valladolid, Spain

Article

Coronary angiography in a 60-year-old woman with non–ST-elevation acute coronary syndrome revealed occlusion of the first marginal branch (Figure 1).

Figure 1.

After predilatation, 2 branches of similar diameter were seen, with significant stenosis of the inferior branch and mild stenosis of the ostium of the superior branch (Figure 1).

A 3 × 28-mm Absorb (Abbott Vascular, California, USA) bioabsorbable vascular scaffold was implanted in the first marginal branch toward the inferior branch. After visualization of severe stenosis of the ostium of the jailed superior branch, a second 3 × 18-mm Absorb scaffold was implanted using the Culotte technique, followed by kissing balloon dilatation with two 2.5-mm NC (noncompliant) balloons to 6 atmospheres (to avoid overexpansion of the proximal zone) and subsequent postdilatation of the first marginal branch-inferior branch (3 × 15-mm NC balloon) (Figure 1).

Follow-up optical coherence tomography (Figure 2, video 1 of the supplementary material) revealed expansion and correct apposition of almost all of the struts. Some struts showed slight malapposition (Figure 2, asterisk). There was also marked malapposition of a strut possibly corresponding to a connector at the bifurcation (Figure 2, arrows).

Figure 2.

The scheduled 12-month follow-up (Figure 1, Figure 3, and video 2 of the supplementary material) showed adequate endothelial coverage, even in the proximal segment and at the malappositioned strut at the carina (Figure 3, arrows).

Figure 3.

The case illustrates that, although treatment of bifurcations with bioresorbable vascular scaffolds is not an approved indication, satisfactory immediate and mid-term results can be achieved with this approach, as long as technical precautions are taken.

SUPPLEMENTARY MATERIAL

Video 1

Video 2

Corresponding author: luverapernasetti@yahoo.com.ar

1885-5857/© 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved

Cookies
x
To improve our services and products, we use cookies (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here.
Cookies policy
x
To improve our services and products, we use cookies (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here.