Delayed Cardiac Tamponade After Stent Fracture

Lorenzo Hernando a,, Roberto del Castillo a, Javier Botas a

a Servicio de Cardiología, Hospital Universitario Fundación Alcorcón, Alcorcón, Madrid, Spain

Article

A 71-year-old man with chronic ischemic heart disease was hospitalized for heart failure. On diagnostic coronary angiography, two severe lesions with considerable calcification were detected in the left anterior descending artery (Figure 1A). Predilation of the entire proximal and medial segment of the descending artery was performed using nondistensible balloons at high-pressure inflation. Subsequently, a 3.5×20-mm drug-eluting stent at 18 atm was implanted, with a good angiographic outcome in 3 postprocedure views (Figure 1B).

Figure 1.

At 60 min following the procedure, the patient showed hypotension, and echocardiography detected a large pericardial effusion. Pericardiocentesis was performed, and 600 mL of hematic pericardial fluid was obtained.

A decision was made to review the previous procedure. At the first contrast injection, coronary perforation with contrast extravasation was seen, with a visible leak in the stent implanted 2 h previously (type III coronary perforation with delayed presentation) (Figure 1C). Correction of the perforation with prolonged inflation failed; hence, we decided to seal the perforation with a polytetrafluoroethylene-covered stent, which was successfully carried out.

On comparison of the image of the empty stent at completion of the first procedure (Figure 2A) with its morphology before the first injection in the second procedure, a small gap is seen in the struts at the superior portion (Figure 2B, circle), where contrast is leaking (Figure 2C, arrow). Therefore, the possible mechanism of the delayed coronary perforation (an unusual complication rarely described in the literature) may have been partial stent fracture.

Figure 2.

Corresponding author: lorenzo_hm@hotmail.com

1885-5857/© 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved

Cookies
x
To improve our services and products, we use cookies (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here.
Cookies policy
x
To improve our services and products, we use cookies (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here.