Symptomatic Late-acquired Coronary Dissection: Value of Intracoronary Images

Roberto del Castillo Medina a,, Lorenzo Hernando Marrupe a, Javier Botas Rodríguez a

a Servicio de Cardiología, Hospital Universitario Fundación Alcorcón, Alcorcón, Madrid, Spain

Article

An 80-year-old man, who was hypertensive, diabetic, and a smoker, was referred to our center due to unstable angina. He had been admitted to another center 3 months previously for a non-Q-wave infarction where he underwent percutaneous revascularization of the anterior descending artery and proximal and middle portions of the right coronary artery using 3 standard stents.

Right coronary angiography showed a double lumen image in the middle third, coinciding with the artery portion treated previously, providing an angiographic image of apparent dissection (Figure 1, arrows). Intracoronary ultrasound confirmed the presence of various phenomena (Figure 2): a) incorrect positioning and underexpansion of both distal stents (arrows); b) contrast transfer to a parallel space with a semicircular cross-section (asterisk); and c) persistence of the intima-medial interface in the vessel wall (arrow tip) and the presence of an intimal/neointimal layer covering the outer surface of the stent.

Figure 1.

Figure 2.

The potential causes of these findings could have been the following: a) unsuitable selection of stent size in an artery with spasm and thrombus; b) partially subintimal trajectory of the stents; and c) dissection/intramural hematoma after stent implantation and late double lumen development due to reabsorption of the thrombotic content, or a combination of these causes.

An angioplasty was performed on the stent with appropriately-sized high pressure non-compliant balloons to position the stents properly and obliterate the adjacent lumen (Figure 3). The intracoronary ultrasound made a decisive contribution to the choice of materials and helped optimize the result.

Figure 3.

Corresponding author: rcastillo@fhalcorcon.es

1885-5857/© 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved

Cookies
x
To improve our services and products, we use cookies (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here.
Cookies policy
x
To improve our services and products, we use cookies (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here.