Publish in this journal
Journal Information
Vol. 61. Issue 6.
Pages 640-643 (June 2008)
DOI: 10.1016/S1885-5857(08)60194-2
Full text access
Percutaneous Closure of Patent Foramen Ovale in Young Patients With Cryptogenic Stroke: Long-Term Follow-Up
Cierre percutáneo de foramen oval permeable en pacientes jóvenes con ictus criptogénico: seguimiento a largo plazo
Visits
...
Francisco Mazuelosa, José Suárez de Lezoa, Manuel Pana, Dolores Mesaa, Mónica Delgadoa, Martín Ruiza, Soledad Ojedaa, Fátima Estebana
a Servicio de Cardiología, Hospital Universitario Reina Sofía, Córdoba, Spain
This item has received
...
Visits
(Daily data update)
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Tables (2)
TABLE 1. Study Protocol
TABLE 2. Patients' Baseline and Echographic Characteristics
Show moreShow less
Figures (2)
Percutaneous closure of patent foramen ovale (PFO) has been proposed as a therapeutic option for cryptogenic stroke. The aim of this article was to describe the experience with this treatment at our center. Up until February 2006, percutaneous closure of PFO was carried out in 52 patients who presented with one or more cryptogenic strokes or transient ischemic attacks. The procedure was carried out under anesthesia and was guided by transesophageal echocardiography. The overall success rate was 100%. Transesophageal echocardiography carried out immediately after device implantation found no evidence of right-to-left shunting in 27 patients. During a mean follow-up of 26 months in 49 patients, none presented with a new ischemic episode or with complications attributable to the device. Echocardiographic follow-up showed that the foramen ovale had been completely sealed in all cases.
Keywords:
Patent foramen ovale
Cerebral ischemia
Percutaneous closure
El cierre percutáneo del foramen oval permeable es una de las opciones terapéuticas propuestas para el ictus criptogénico. El objetivo del presente trabajo es describir la experiencia de nuestro centro. Hasta febrero de 2006, se ha tratado con cierre percutáneo de foramen oval permeable a 52 pacientes que habían presentado uno o más ictus o ataques isquémicos transitorios criptogénicos. El procedimiento se realizó con anestesia y guiado por ecocardiografía transesofágica (ETE). La tasa de éxito primario fue del 100%. Inmediatamente tras el implante del dispositivo, en 27 pacientes no se observó paso derechaizquierda por ETE. Tras un seguimiento clínico medio de 26 meses en 49 pacientes, ninguno ha tenido nuevos episodios isquémicos ni complicaciones atribuibles al dispositivo. El seguimiento ecocardiográfico mostró en todos un sellado completo del foramen oval.
Palabras clave:
Foramen oval permeable
Isquemia cerebral
Cierre percutáneo
Full Text

INTRODUCTION

Studies have shown the association between patent foramen ovale (PFO) and cryptogenic stroke. Currently, treatment of these patients is controversial, although data exist that favor percutaneous PFO closure.1 The objective of the present report is to study immediate and long-term follow-up results for a consecutive series of patients with cryptogenic stroke and percutaneous PFO closure.

METHODS

From January 2000 thru February 2006, 52 patients aged <60 years diagnosed with PFO and stroke underwent percutaneous closure in our hospital. All were diagnosed with acute stroke or transient ischemic attacks (TIA), and underwent full clinical examination (Table 1). Diagnosis of cardioembolic pathology was ruled out by echography. Foramen permeability was analyzed with Gelafundin 4% injected via a peripheral vein in baseline conditions and following the Valsalva maneuver.

Percutaneous foramen closure was indicated in patients with cryptogenic stroke, PFO, some of the following echocardiographic criteria, and considered at risk of new neurologic event as described elsewhere2,3: recurrence of neurologic clinical events, substantial contrast shunting at rest (>20 microbubbles), interatrial septal aneurysm (ISA) defined as 311 mm total excursion in left and/or right atrium,4 and substantial septum primum membrane mobility (>6 mm).

Implantation was undertaken with angiographic control and general anesthesia due to the difficulty entailed in keeping patients under transesophageal echocardiographic (TEE) monitoring during the procedure. Prior to implantation, pulmonary artery angiography in cava inferior was conducted to evaluate spontaneous left-to-right and right-to-left shunting (Figure 1). Later echographic bubble contrast was injected to determine right-to-left shunting by TEE in baseline conditions and after the forced expiratory respiration maneuver; this was repeated after implantation (Figure 1).

Figure 1. A: baseline angiography with contrast injection in right atrium showing right-to-left shunting. B: angiography of implanted device, sealing foramen ovale, with contrast injection in right atrium. C: transesophageal echography of right-to-left contrast shunting. D: transesophageal echography of implanted device, without right-to-left shunting.

We chose to deploy devices with a major diameter smaller than the total interatrial septum length determined by TEE retroaortic projection (Figure 2). In patients with septal aneurysm, we opted for a device slightly larger than the aneurysm base measure. Choice of device to deploy— Amplatzer (AGA Medical, Minnesota, USA), Intrasept (Cardia Inc., Minnesota, USA), or Helex (W.L. Gore, Arizona, USA)—was left to individual operators except in patients with septal aneurysm, when Amplatzer devices were always used. We had access to 18, 25, and 35 mm Amplatzer devices and 20, 25, and 30 mm Helex devices.

Figure 2. Transesophageal echography. A: aneurysm of interatrial septum. B: anatomic patent foramen ovale (arrow). C: measuring septum to choose device size (arrow). D: image of implanted device.

All patients received prophylactic antibiotic treatment following implantation and antithrombotic treatment with dalteparin (10 000 IU/day for 1 month) and aspirin (150 mg/day indefinitely).5,6

We conducted transthoracic echography (TTE) using second harmonic imaging and contrast prior to discharge and clinical follow-up and contrast echography at 6 months and 1 year, and in subsequent annual clinical follow-ups.

We present quantitative variables as mean (SD) and qualitative variables as percentages of the total. Data analysis was with SPSS 8.0.

RESULTS

We performed percutaneous PFO closure in 52 patients aged <60 years. Table 2 presents their clinical and echographic characteristics. Devices were successfully implanted in all patients. We used Amplatzer devices in 40 (76%) patients, Helex in 11 (22%), and Intrasept in 1. In 4 patients, we used an Amplatzer device for cribriform interatrial communication closure as they presented multiple membrane perforations. Device size was 35 mm in 25% of patients, 30 mm in 12%, 25 mm in 54%, and £20 mm in 10%.

All patients with ISA presented a base measure of >25 mm, so we used 35 mm Amplatzer devices. At the end of the procedure, we found residual bubble shunting in 12 patients (24%) in baseline situation and in 25 patients (48%) following forced expiration; this was considered mild in 11 patients.

No major complications or device embolization occurred. At discharge, we found residual shunting in 2 (4%) patients using contrast TTE.

We have conducted follow-up of 49 patients for a median of 26 months (range, 2-72; percentiles 25-75, 8-39). Three patients were lost to follow-up.

No clinical neurologic events, or events of any other type attributable to the procedure or device (endocarditis, embolization, fracture) occurred. At 6 months, the late TTE study found no residual shunting in any patient.

DISCUSSION

Since Overell et al's meta-analysis,7 the association between PFO and cryptogenic stroke has been clear and contrast TEE has proven the most adequate method of diagnosis.8 In patients with PFO, several studies have described risk factors for stroke3 similar to those we used as indications for closure.9

In the absence of randomized studies comparing medical treatment with percutaneous closure, the high rate of recurrence with medical treatment, as much as 13%,10 and the existence of studies that favor percutaneous closure11 make this a widely-used option. In Spain, in 2005, 182 percutaneous PFO closure procedures were performed.12

Incidence of recurrence following closure varies, ranging from 0.6% to 7.8%.11 In our study, there has been no recurrence. This may be due to the antithrombotic drug regimen used—not described in other studies— possible favoring adequate, rapid sealing of the device without thrombotic aggregation. Despite residual shunting following discharge in 4%, at 6-month echocardiographic follow-up no patient presented shunting, which coincides with results described elsewhere.13 In contrast, the major complications associated with percutaneous closure— in 1.5% of patients in the series described1—were not present in our study.

While procedures were conducted with TEE guidance, anesthesia can be avoided by using intracavity echography.

In our experience, percutaneous closure is a safe option in young patients with cryptogenic stroke and PFO, without recurrence or events in the long-term.

Limitations

The absence of a control group of patients with cryptogenic stroke and PFO treated medically prevents us from comparing both therapeutic options, but the rate of recurrence of neurologic events in patients with medical treatment was what motivated our decision to use percutaneous closure. The late evolution of these patients seems to endorse this decision. The finalization of randomized studies under way at the time of writing, and prolonged follow-up should lead to a more definitive ratification of these findings.


Correspondence:
Dr. F. Mazuelos Bellido.
Servicio de Cardiología. Hospital Reina Sofía. Avda. Menéndez Pidal, s/n. 14004 Córdoba. España.
E-mail: franciscomazuelos@gmail.com

Received September 12, 2007.
Accepted for publication November 7, 2007.

Bibliography
[1]
Khairy P, O'Donnell CP, Landzberg MJ..
Transcatheter closure versus medical therapy of patent foramen ovale and presumed paradoxical thromboemboli: a systematic review..
Ann Intern Med, 139 (2003), pp. 753-60
[2]
Mas JL, Arquizan C, Lamy C, Zuber M, Cabanes L, Derumeaux G, et al..
Recurrent cerebrovascular events associated with patent foramen ovale, atrial septal aneurysm, or both..
N Engl J Med, 345 (2001), pp. 1740-6
[3]
Mesa D, Franco M, Suárez de Lezo J, Muñoz J, Rus C, Delgado M, et al..
Prevalencia de foramen oval permeable en pacientes jóvenes con accidente isquémico cerebral de causa desconocida..
Rev Esp Cardiol, 56 (2003), pp. 662-8
[4]
Pearson AC, Nagelhout D, Castello R, Gomez CR, Labovitz AJ..
Atrial septal aneurysm and stroke: a transesophageal echocardiographic study..
J Am Coll Cardiol, 18 (1991), pp. 1223-9
[5]
Pan M, Suárez de Lezo J, Medina A, Romero M, Segura J, Mesa D..
Tratamiento percutáneo de los aneurismas del septo interauricular..
Rev Esp Cardiol, 58 (2005), pp. 222-6
[6]
Rodríguez M, Suárez de Lezo J, Pan M, Romero M, Segura J, Pavlovic D, et al..
Cierre percutáneo de comunicaciones interauriculares grandes..
Rev Esp Cardiol, 56 (2003), pp. 888-93
[7]
Overell JR, Bone I, Lees KR..
Interatrial septal abnormalities and stroke: a meta-analysis of case-control studies..
Neurology, 55 (2000), pp. 1172-9
[8]
Hara H, Virmani R, Ladich E, Mackey-Bojack S, Titus J, Reisman M, et al..
Patent foramen ovale: current pathology, pathophysiology, and clinical status..
J Am Coll Cardiol, 46 (2005), pp. 1768-76
[9]
de Castro S, Cartoni D, Fiorelli M, Rasura M, Anzini A, Zanette EM, et al..
Morphological and functional characteristics of patent foramen ovale and their embolic implications..
Stroke, 31 (2000), pp. 2407-13
[10]
Nedeltchev K, Arnold M, Wahl A, Sturzenegger M, Vella EE, Windecker S, et al..
Outcome of patients with cryptogenic stroke and patent foramen ovale..
J Neurol Neurosurg Psychiatry, 72 (2002), pp. 347-50
[11]
Windecker S, Wahl A, Nedeltchev K, Arnold M, Schwerzmann M, Seiler C, et al..
Comparison of medical treatment with percutaneous closure of patent foramen ovale in patients with cryptogenic stroke..
J Am Coll Cardiol, 44 (2004), pp. 750-8
[12]
Secci??n de Hemodin??mica. SEC; 2005 [citado 7 Sep 2007]. Disponible en: http://www. hemodinamica.com/C_enlaces/sec_actividad/reg_anual/ resultados/2005_v1_04062006.pdf
[13]
Braun M, Gliech V, Boscheri A, Schoen S, Gahn G, Reichmann H, et al..
Transcatheter closure of patent foramen ovale (PFO) in patients with paradoxical embolism. Periprocedural safety and mid-term follow-up results of three different device occluder systems..
Eur Heart J, 25 (2004), pp. 424-30
Idiomas
Revista Española de Cardiología (English Edition)

Subscribe to our newsletter

Article options
Tools
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

es en
Política de cookies Cookies policy
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación. Si continua navegando, consideramos que acepta su uso. Puede cambiar la configuración u obtener más información aquí. To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here.