ISSN: 1885-5857 Impact factor 2025 4.2
Vol. 78. Num. 8.
Pages 724-735 (August 2025)

Review article
Transcatheter aortic valve implantation in bicuspid aortic valves: present and future

Implante percutáneo de válvula aórtica en válvulas aórticas bicúspides: presente y futuro

Alberto AlperiabRaquel del ValleaIsaac PascualabcPaula AntunaaMarcel AlmendárezaRut ÁlvarezaDaniel Hernández-VaqueroabPablo Avanzasabcd
https://doi.org/10.1016/j.rec.2025.02.008

Options

Imagen extra
Rev Esp Cardiol. 2025;78:724-35
Abstract

The prevalence of bicuspid aortic valves (BAV) in patients undergoing transcatheter aortic valve implantation (TAVI) is expected to gradually increase over the coming years. However, in the absence of dedicated randomized trials, TAVI outcomes in BAV patients have failed to match those obtained in trileaflet anatomies. This discrepancy is mainly due to varying degrees of valve morphology and calcification, aortic angulation, concomitant aortopathy, and the difficulties of achieving optimal preprocedural anatomic sizing and device selection in the BAV setting. In this review, we aim to outline the current state of knowledge in the BAV and TAVI field, evaluate the main challenges faced by TAVI operators when dealing with these anatomies, summarize novel approaches for sizing and preprocedural evaluation, and provide a glimpse into the future of this interesting and evolving field.

Keywords

Bicuspid aortic valve
Transcatheter aortic valve replacement
Aortic stenosis
INTRODUCTION

Aortic stenosis (AS) is one of the most common heart valve disorders in Western countries.1 Transcatheter aortic valve implantation (TAVI) has become a widely adopted treatment for severe AS throughout the spectrum of surgical risk profiles,2,3 due to its favorable outcomes compared with surgical aortic valve replacement (SAVR).4,5

Bicuspid aortic valve (BAV) stenosis is the most prevalent congenital heart disease, affecting 1% to 2% of the general population.6 It represents a significant proportion of patients undergoing aortic valve replacement in clinical practice, with its prevalence inversely related to patient age.7 Consquently, the expansion of TAVI to lower-risk, younger populations has increased the number of BAV patients referred for the procedure. However, robust clinical evidence in this area remains limited, as the main SAVR vs TAVI trials excluded participants with BAVs.8

In this review, we aim to explore the key challenges associated with transcatheter interventions in patients with BAV, summarize current clinical evidence in the field, and highlight the main gaps in knowledge, as well as future directions of TAVI in this population.

EPIDEMIOLOGY OF BAV AND TAVI

Overall, BAV affects between 1% and 2% of the population in Western countries,6 although its prevalence has been reported to be much higher in certain Asian populations.9 Current registries show significant variation in the prevalence of BAV among Western10 and Japanese TAVI patients11 (5%-10%) compared with Chinese populations, in which BAVs represent up to 48% of TAVI recipients.12 Although the adoption of TAVI in Asia was slower than in the United States and Europe, its use is now expanding rapidly in Asian populations,13 which will significantly increase the number of BAV patients treated with TAVI worldwide.

BAV ANATOMY: CHALLENGES FOR TAVI

Several anatomical factors make TAVI in BAVs more complex compared with the well-characterized trileaflet valve anatomy. These challenges have implications for both procedural planning and intraprocedural decision-making.

BAV classification

Trileaflet aortic valves may have varying degrees of calcification and dimensions, but they share a consistent configuration with 3 distinct cusps and commissures, each associated with a corresponding sinus of Valsalva. In contrast, BAVs show a wide range of configurations. According to the Sievers classification, BAVs are categorized into 3 types (types 0, 1 and 2) based on the number of anatomically distinguishable raphes.14 The term raphe refers to the fused ridge or conjoint area that connects 2 cusps, functioning as an abnormal commissure.

  • -

    Type 0 BAVs lack a raphe and can be further subcategorized based on the position of the 2 cusps (often symmetric and equal in size) into antero-posterior or latero-lateral orientations.

  • -

    Type 1 BAVs have a single raphe, with the most common configuration being right-left cusp fusion, followed by right-noncoronary and left-noncoronary fusions.

  • -

    Type 2 BAVs feature 2 raphes.

Recently, a new proposal for BAV classification has emerged, categorizing the anatomies into:

  • 1.

    Fused with raphe: 2 cusps with a fused raphe and 3 sinuses of Valsalva.

  • 2.

    Fused without raphe: 2 cusps without a raphe.

  • 3.

    Double-sinus BAV: 2 cusps and 2 sinuses without a raphe, similar to Sievers type 0.15

A schematic summary of the current BAV classification is depicted in figure 1.

Figure 1.

Central illustration. Schematic configurations of BAV types according to current nomenclature adoption. Note that 2-sinus BAV refers to type 0 Sievers's BAV, and fused-BAV refers to type 1 Sievers's bicuspid aortic valve. BAV, bicuspid aortic valve; L, left; NC, noncoronary; R, right.

(0.59MB).
Annular dimensions and shape

The aortic annulus in BAVs is generally larger than that of trileaflet patients,16 making BAV patients more likely to be unsuitable for currently available transcatheter heart valves (THV). Additionally, the use of larger systems requires the use of large-bore introducer sheaths, inherently increasing the risk of procedural vascular complications. Importantly, trileaflet valves usually exhibit almost tubular shapes, with minimal differences in dimensions between the left ventricular outflow tract (LVOT), the annulus, and the supra-annular planes. In contrast, BAVs often show elliptical annuli and tapered configurations, in which the supra-annular diameter at the site of the raphe is smaller than the annular diameter. This configuration is observed in more than 70% of cases.17 Furthermore, while the point of greatest restriction for THV expansion in TAVI has been assumed to be the aortic annulus, in BAVs it may be located elsewhere (ie, raphe, commissural plane).

Concomitant aortopathy

Patients with BAV often have associated aortic conditions, including aneurysms, tubular or elongated horizontal aortic roots, and coarctations.18,19 High-risk and inoperable patients may undergo TAVI despite the presence of aortic aneurysms or prior postcoarctation interventions, which significantly increase the risk of major procedural complications such as aortic dissection and rupture.

Calcification

Patients with BAVs frequently exhibit substantial asymmetrical calcification involving the aortic leaflets, aortic annulus, LVOT, sino-tubular junction, and the raphe (if present). A recent study showed that both annular and LVOT calcification were associated with THV underexpansion and eccentricity in patients receiving balloon-expandable valves (BEV). Importantly, the combination of underexpansion and eccentricity was associated with valve-related outcomes (ie, leaflet thickening, restricted leaflet motion, paravalvular leak [PVL]).20

Coronary asymmetry and commissural alignment

In recent years, the potential to achieve commissural alignment during SEV implantation has gained momentum in the TAVI field. Proper alignment between the native and bioprosthetic commissures may facilitate coronary reaccess, enhance coronary perfusion, and optimize hemodynamic valve performance, potentially contributing to improved valve durability.21 In patients with trileaflet aortic valves, pronounced native commissural asymmetry is rare, as most commissural angles are close to 120°, with the coronary artery take-offs positioned at the center of each corresponding cusp. However, this is not the case for BAVs, where more than 50% of cases show severe commissural asymmetry and a predominant cusp. Notably, coronary artery take-off in BAV patients is situated higher than in those with trileaflet aortic valves, and the prevalence of concomitant coronary anomalies is twice as high in the former group.22 In fact, BAV anatomy also affects the risk of coronary occlusion in future TAVI-in-TAVI procedures, as type 0 BAV is associated with lower rates of high-risk features for coronary occlusion at the time of TAVI-in-TAVI compared with type 1 BAV and native trileaflet anatomies.23

PREPROCEDURAL WORKUP FOR BICUSPID TAVI: CARDIAC IMAGING

The severity of AS, along with the morphology and calcific burden of the valvular complex, should be carefully assessed. Pre-TAVI cardiac imaging plays a critical role in determining patient eligibility by providing essential information on sizing and structural considerations for each THV device.

Echocardiography

Apart from diagnosing the severity of AS based on gradients, area and flow, TTE also assesses the presence of other valvular diseases and biventricular function. However, TTE can distinguish between bicuspid and tricuspid aortic valves in only 50% to 70% of cases.24,25 Therefore, the actual prevalence of BAV may be significantly underestimated by TTE.

Cardiac computed tomography

Contrast-enhanced, thin-sliced cardiac computed tomography provides submillimetric spatial resolution, facilitating the assessment of aortic morphology and annular sizing. Cardiac computed tomography is definitive for diagnosing bicuspid vs tricuspid aortic valves and also provides an assessment of the LVOT, aortic root, determination of coronary heights, and identification of concomitant ascending aortopathy.26

Annular and supra-annular sizing

Cardiac computed tomography assessment of BAV-TAVI is subject to ongoing refinement, with particular focus on strategies for annular and supra-annular sizing before device selection in recent years. Traditionally, sizing has relied on the aortic annular plane (or virtual basal ring), defined by the hinge points of the cusps—3 points in trileaflet anatomies and fused BAVs, and 2 points in nonfused type 0 BAVs. However, additional anatomical features require careful evaluation in BAV cases. The intercommissural diameter (ICD) above the aortic annulus is highly relevant, as it enables the categorization of the morphology of the aortic valve and root composite into flared (ICD larger than the perimeter-derived annular diameter), tubular (ICD similar to the perimeter-derived annular diameter), and tapered (ICD smaller than the perimeter-derived annular diameter) anatomies. This measure can be obtained at a standardized height above the annulus (commonly 4mm) or at the site of maximal raphe length. A particularly challenging subset of patients are those in which the BAV shows a raphe-type variant (Sievers type 1) combined with a tapered configuration.

Several approaches have been proposed to determine the optimal sizing method for BAV-TAVI, each with its advantages and drawbacks. The main considerations are summarized in table 1.

Table 1.

Main available methods as alternative sizing strategies for bicuspid aortic valve TAVI

Sizing strategy characteristics  BAVARD26  LIRA27  CASPER28  CIRCLE29 
Sizing method  -4 mm above the virtual basal ring  -Plane that cuts the raphe at its maximum protrusion  -Raphe assessment at maximal length plane  -Projected circle of the identical diameter to the proposed BEV is placed at 3-mm-Increments starting at the annular plane, upto the sinotubular junction 
Variables to consider  -Annulus mean perimeter-derived diameter-ICD  -Annular perimeter-Perimeter at the level of implantation at the raphe plane tracing interior borders of the leaflets  -Aortic calcium volume-Raphe length/aortic annular diameter ratio-Aortic annulus perimeter-derived diameter-Calcium volume at the site of the raphe  -Flared vs tapered configuration-Circle 1 size less than annular sizing is also projected for candidates for supra-annular sizing-Calcification 
Cohort of study  101 participants  65 participants  19 participants  NA 
Cohort of validation  NA  20 participants  21 participants  NA 
Applicability  SEV and BEV  SEV and BEV  SEV and BEV  BEV 
Results  NA  -100% device success-0% ≥ moderate PVL  -100% procedural success-0% ≥ moderate PVL  NA 
Advantages  -Easy to obtain-Consistent plane height for measurement  -Identifies the plane of greatest resistance irrespective of distance from aortic annulus  -Integration of several features-Takes into account calcium burden and distribution  -Fast and reproducible.-Helps understand sealing zone 
Disadvantages  -Might miss the plane of greatest resistance to transcatheter heart valve expansion  -Experienced CCT operators-Some anatomies difficult to ascertain the exact internal border  -Variability due to subjective measurement of the calcium severity of the raphe.-Higher complexity of the algorithm than other methods-Validation cohort only in SEVs  -Qualitative method-No validation in clinical practice 

BEV, balloon-expandable valve; CCT, cardiac computed tomography; ICD, intercommissural diameter; NA, not available; PVL, paravalvular leakage; SEV, self-expandable valve; TAVI, transcatheter aortic valve implantation.

The BAVARD (Bicuspid Aortic Valve Anatomy and Relationship With Devices) approach measures the ICD 4mm above the basal ring, yielding an approximately 14% prevalence of tapered anatomic configurations.27 This approach may underestimate the actual prevalence of tapered BAVs, as the distance between the planes representing the aortic annulus and the maximal raphe length typically ranges from 7 to 8mm.

The level of implantation at the raphe (LIRA) method defines the expected anchoring plane as the location where the calcific/fibrotic raphe has its maximum protrusion along the aortic root.28 In a series of 20 patients, all valve sizes were selected according to the LIRA plane, resulting in optimal early outcomes.

The CASPER (Calcium algorithm sizing for bicuspid evaluation with raphe) algorithm for THV sizing in raphe-type BAVs considers calcium volume, the ratio between the raphe length and the perimeter/area-derived annular diameter, and calcium distribution at the raphe site. The use of this method may lead to THV undersizing in up to 70% of self-expandable devices, without an apparent trade-off in terms of residual regurgitation or valve malposition.29

Finally, the CIRCLE method, which is used exclusively for BEV, projects a circle identical to the diameter of the intended device in 3-mm increments beginning at the annular plane. When the circle extends beyond the commissures, especially in association with a calcified raphe or severely calcified nonfused cusp, there is a high risk of commissural rupture, and a downsizing approach should be considered.30

Recently, the largest registry to date for BAV-TAVI has evaluated the accuracy and clinical impact of supra-annular sizing (ie, at the site of greatest resistance against THV expansion, where the raphe is more prominent) compared with standard virtual basal ring annular sizing (ie, based on the hinge points of the aortic cusps). In 186 (27%) of 696 cases, downsizing was necessary compared with the standard annular sizing technique, and clinical outcomes such as residual leakage, pacemaker implantation, and the need for a second valve were comparable to those observed when no downsizing was needed. However, higher gradients and a greater rate of patient-prosthesis mismatch were observed when supra-annular sizing was used.17,31 Proposed algorithms for THV sizing selection in the context of BAV are displayed in figure 2 (for BEVs) and figure 3 (for SEVs). Figure 4 and figure 5 display an illustrative case in this context.

Figure 2.

Proposed algorithm as a sizing strategy for BEV implantation in BAVs. BAV, bicuspid aortic valve; BEV, balloon-expandable valve; THV, transcatheter heart valve; VBR, virtual basal ring.

(0.73MB).
Figure 3.

Proposed algorithm as a sizing strategy for SEV implantation in BAVs; BAV, bicuspid aortic valve; SEV, self-expandable valve; THV, transcatheter heart valve; VBR, virtual basal ring.

(0.46MB).
Figure 4.

Case of a BAV-TAVI. A: fused raphe-type Sievers 1 BAV, with left-right cusp fusion. B-C: severe eccentric calcification mainly involving the noncoronary cusp with LVOT extension. D: aortic annulus measurements following the standard virtual basal ring assessment (perimeter: 81.3mm, area: 524 mm2, perimeter-derived diameter: 25.9mm). E: LVOT measurements (perimeter 82.5mm). F: ICD of 25.6mm at the LIRA plane. G: perimeter (70.1mm) at LIRA plane. In conclusion, tapered BAV as the ICD and perimeter at LIRA plane are smaller than the annular perimeter-derived diameter and perimeter. BAV, bicuspid aortic valve; ICD, intercommissural diameter; LC, left coronary; LIRA, level of implantation at the raphe; LVOT, left ventricular outflow tract; NC, noncoronary; RC, right coronary; TAVI, transcatheter aortic valve implantation.

(0.64MB).
Figure 5.

Transcatheter heart valve sizing selection for case in figure 4. A: fibrotic raphe-type without significant calcification at raphe site. Orange and blue arrows represent the views from which figures D and E were obtained by fluoroscopy. B: raphe length of 7mm. The ratio between raphe length (7mm) and annular perimeter-derived diameter (25.9mm) was 0.27. C: calcification volume of 547 mm3. D: right caudal fluoroscopic view (parallel to the intercommissural diameter) after Evolut FX implantation. Dotted yellow line represents the annular plane; red dotted line represents the plane of the raphe (device restriction at this level). E: left cranial fluoroscopic view (orthogonal to the intercommissural diameter) after Evolut FX implantation. No device restriction is observed in this view. F: circle method for a 26-mm BEV implantation that fits the patient's supra-annular anatomy. SEV sizing: fused raphe-type tapered BAV with 1 risk criteria (calcium volume), a conservative oversizing between 5% to 20% is advised. An Evolut FX 29-mm device (11.7% oversizing) was selected. In a trileaflet case, the 34-mm size that provided 30% oversizing and better fitted the LVOT dimensions would have been chosen. BEV sizing: the circle method demonstrates that a 26-mm device perfectly fits the supra-annular anatomy. Considering the presence of 1 risk criterion (calcium volume), a sizing according to the aortic annulus area aiming at −5% oversizing would have been advised. In the case of a 26-mm SAPIEN 3 device, the inflation at 1 cc below nominal pressure (−4.8% oversizing) would have been selected. In trileaflet anatomy, inflation at nominal or supra-nominal pressure aiming at +5% to 15% oversizing would have been encouraged. BEV, balloon-expandable valve; Ca., calcification; LC, left coronary; LVOT, left ventricle outflow tract; NC, noncoronary; RC, right coronary; SEV, self-expandable valve.

(0.34MB).
Coronary symmetry and alignment

As previously mentioned, not all anatomies fulfill the criteria for cusp and coronary symmetry, and this is more pronounced in the BAV setting. Regarding aortic valve cusp symmetry (the angle between 2 neighboring commissures), it has been demonstrated that 17.5% of trileaflet aortic valves show moderate (> 130°) or severe (> 135°) asymmetry, and that the rate increases to 69% in the case of BAVs. In addition, the predominant cusp in BAV patients is the noncoronary cusp in most (85%) cases.32 Moreover, it has been reported that, even if a perfect orientation aiming to minimize the overlap between the THV commissures and coronary ostia were achieved, the prevalence of moderate or severe neocommissural overlap (< 30°) with the native coronary arteries would remain as high as 41% in BAV patients compared with 10% in those with a trileaflet configuration. This is particularly important in the setting of type 0 BAVs, as the angle between the 2 coronary ostia is frequently much larger than the exact 120° between neocommissures in current THVs, preventing optimal alignment regardless of the position of the implanted device.33 Thus, obtaining optimal commissural and coronary alignment with newly implanted THVs in BAV patients is cumbersome due to cusp asymmetry and coronary ostia eccentricity. In such instances, a tailored implantation approach that prioritizes isolating the ostium at greatest risk for occlusion may be required.

TAVI OUTCOMES IN BAV PATIENTSBicuspid vs trileaflet aortic valves

Retrospective studies reporting TAVI outcomes among bicuspid and trileaflet AS patients have shown a lower rate of device success among BAV patients, mainly due to a higher probability of residual significant PVL.10 Additionally, a large meta-analysis including 17 observational studies and more than 180 000 patients revealed that BAV patients had a higher risk of moderate or severe PVL (risk ratio [RR], 1.42; 95% confidence interval, 1.29-1.58; P<.0001), annular rupture (0.3% vs 0.02%; P=.014), and stroke (2.4% vs 1.6%; P=.015).34 An analysis from the Society of Thoracic Surgeons/Transcatheter Valve Therapy (STS/TVT) registry demonstrated a lower rate of device success among BAV patients compared with their trileaflet counterparts; however, those differences disappeared when only newer-generation implantations were considered.35

TAVI vs SAVR in BAV

The evidence for this comparison primarily comes from observational registries due to the lack of purposefully designed randomized trials. Thus far, a propensity-matched analysis has yielded comparable results for early and 1-year mortality (2.7% vs 2.9%; P=.90, and 7.4% vs 9.0%; P=.34, respectively) and for stroke rates (3.7% vs 4.0%; P=.90) between both techniques. New-onset atrial fibrillation was more frequent after SAVR (36.3% vs 5.1%; P<.001), while the risk for new permanent pacemaker implantation was higher after TAVI (12.2% vs 7.6%; P=.009).36 The largest study to date, including patients from the American nationwide readmission database (52 476 bicuspid SAVR and 3855 bicuspid TAVI patients) provided statistically comparable results for early mortality and readmission after adjustment.37 Finally, a recent meta-analysis of 7 observational studies yielded comparable outcomes for mortality, stroke, and PVL with the 2 techniques, with the surgical approach associated with a higher risk for bleeding events and TAVI showing a greater risk of conduction disturbances.38 A summary of the main studies comparing TAVI vs SAVR in propensity-matched or randomized populations is displayed in table 2.36,39–43The only randomized trial in which BAV patients were not directly excluded was the NOTION-2 trial, which compared TAVI and SAVR outcomes in patients aged ≤ 75 years at low surgical risk. There were 100 BAV patients among the 370 patients included and a subanalysis comparing outcomes among BAV anatomies demonstrated a clear trend toward worse outcomes (mainly stroke, pacemaker implantation, and moderate or greater PVL) with the percutaneous approach. Notably, SAVR yielded better outcomes for BAV than for trileaflet patients, whereas the opposite was observed for TAVI.43 The results of this trial raise a word of caution regarding the spread of TAVI to very young (< 75 years-old) BAV patients, as SAVR seems to be a better option for them despite longer hospitalization and recovery times.

Table 2.

Main studies comparing TAVI vs SAVR outcomes in BAV patients

Study  Type of study  N  BAV type  Mortality  Stroke  PPI  Major bleeding 
Elbadawi et al.39  ObservationalPS-matched  TAVI: 975SAVR: 975  NA  30 (3.1)30 (3.1)  20 (2.1)25 (2.6)  132 (138)45 (4.6)  230 (23.6)435 (44.6) 
Mentias et al.36  ObservationalIPW-matched  TAVI: 699SAVR: 699  NA  15 (2.2)16 (2.3)  19 (2.7)20 (2.9)  85 (12.2)53 (7.6)  NA 
Husso et al.40  ObservationalPS-matched  TAVI: 75SAVR: 75  Type 0: 16.5%Type 1: 81.6%  1 (1.3)4 (5.3)  3 (4)6 (8)  8 (11.4)4 (5.5)  11 (14.7)61 (81.3) 
Majmundar et al.41  ObservationalPS-matched  TAVI: 1393SAVR: 1393  NA  10 (0.7)26 (1.8)  41 (2.9)45 (3.2)  155 (11.8)113 (8.6)  35 (2.5)145 (10.5) 
Chen et al.42  ObservationalPS-matched  TAVI: 797SAVR: 797  NA  13 (1.6)19 (2.4)  19 (2.4)18 (2.3)  73 (9.2)50 (6.3)  NA 
Jørgensen et al.43  Randomized trial, subgroup analysis  TAVI: 49SAVR: 51  Type 0: 7%Type 1: 93%  2 (4.1)1 (2)  3 (6.1)0  7 (14.6)4 (8.5)  2 (4.1)7 (13.7) 

BAV, bicuspid aortic valve; IPW, inverse probability of treatment weighting; NA, not available; PPI, permanent pacemaker implantation; PS, propensity score; SAVR, surgical aortic valve replacement; TAVI: transcatheter aortic valve implantation.

The data are presented as No. (%).

Single-arm trials in BAV-TAVI

The LRT (Low Risk Trial) was a feasibility study to test the safety and efficacy of TAVI in low-risk patients with severe BAV AS. A total of 61 patients were enrolled, with a mean age of 68.6±7.4 years, and most of them (n=47; 78.3%) had fused Sievers type 1 BAV. There was no in-hospital mortality and no need for a second THV, and the rates of stroke (1.6%) and new pacemaker implantation (13.1%) were relatively low. There were no cases of moderate or severe PVL at discharge. The 2-year results of this single-arm trial showed 6.2% and 3.1% 2-year rates for stroke and infective endocarditis, respectively. Importantly, among the 65 patients who completed the 2-year echocardiographic follow-up, no cases of moderate or severe PVL remained patent.44 For the Evolut THV (Medtronic, USA), 150 patients were enrolled in the low-risk bicuspid study (single-arm). Most of the patients (90.7%) had fused (Sievers type 1) BAV, and 30-day all-cause mortality was 0.7%, with new pacemaker implantation at 15.1%, and no patients exhibited worse than mild PVL. Those positive results remained consistent at 3-years.45

Recently, the results of the BIVOLUTFX prospective registry on Evolut FX implantation in BAV demonstrated 30-day mortality and stroke rates of 2.6% and 4.6%, respectively.46 In addition, a second valve was needed in 2% of patients, whereas 2.7% experienced cardiac tamponade. Moreover, the 1-year rate of moderate/severe PVL was above 4%. These results, based on recent TAVI cohorts utilizing new-generation devices, highlight the difficulties of SEV implants in BAVs.

Finally, the P3-BAV registry reported on 169 BAV patients receiving the SAPIEN 3 BEV (Edwards Lifesciences, USA), showing a 6.8% rate for the combined event of 30-day death, stroke, or rehospitalization. Notably, 47% of the patients screened for this single-arm continued access protocol were excluded based on anatomical conditions such as severe LVOT or raphe calcification and ascending aorta diameter,47 outlining that selection bias could translate into significant anatomical differences between single-arm trials and real-life patients in the BAV field.

TRANSCATHETER VALVE TYPE SELECTION FOR BICUSPID TAVI

There is a paucity of data on direct valve comparisons among THV types for the treatment of BAV AS.

SAPIEN 3 and Evolut devices

The group of new-generation SAPIEN BEVs (SAPIEN 3, SAPIEN Ultra, SAPIEN Ultra Resilia) and Evolut SEVs (Evolut R, PRO, PRO+, FX) has been the most widely used and studied THVs in the TAVI field. The only randomized trial to date comparing the self-expandable Evolut R/PRO and balloon-expandable SAPIEN 3 devices failed to demonstrate significant differences. Furthermore, the inclusion of a substantial number of BAV patients was unlikely.48 In a prior report, 353 patients with BAV who underwent TAVI with the SAPIEN 3 (n=242) and Evolut R/Pro (n=111) valve systems were evaluated after propensity matching. The results demonstrated comparable outcomes regarding mortality and periprocedural complications. However, there were significant differences in valve hemodynamics, with a higher rate of moderate-severe PVL for Evolut patients (0.8% vs 10.8%; P<.001), although residual gradients/valve area favored Evolut implantations. Notably, most of the Evolut patients included in this study might have received the Evolut R system, which lacks the antiparavalvular leakage properties of the PRO and PRO+ devices.49,50

Interestingly, an analysis from the BEAT registry, which divided the cohort into 3 subgroups based on annular size, identified an inflection point between small-medium (annular area<575 mm2 and perimeter <85mm) and large annuli with concerning valve performance and residual aortic regurgitation for new-generation BEV and SEV systems in the BAV setting. Lower residual gradients and higher performance indexes were found for Evolut R/PRO in patients with small-medium annular sizes, with no significant trade-off in terms of residual ≥ moderate PVL. However, in the large annuli group, there was a higher rate of significant residual PVL for the Evolut R/PRO system, with no differences in gradients or area.51

ACURATE Neo

There are no data directly comparing the ACURATE Neo system (Boston Scientific, USA) with other devices in BAV. However, similar to other systems, there is a trend toward higher rates of PVL and stroke in BAV patients compared with those with trileaflet anatomy.52

Myval and Hydra

It should be noted that some devices that have been historically less used in Western countries are primarily used in other regions. Interestingly, the BEV Myval (Meril Life Sciences, India), which offers a wider range of intermediate sizes compared with other BEVs, was evaluated against the SAPIEN 3 Ultra and Evolut systems in BAV anatomies. After propensity matching, 80 patients per device were evaluated: Myval patients exhibited no mortality and a very low risk for 30-day complications such as stroke (1.3%), major vascular complications (3.8%), pacemaker implantation (10%), and ≥ moderate PVL (1.9%). These findings were slightly better than those obtained with the SAPIEN and Evolut devices.53,54 Another device developed in India, the Hydra system (Sahajanand Medical Technologies, India), has demonstrated promising early results,55 although reports in BAVs are lacking.

VenusA, J-Valve, VitaFlow, Taurus

A substantial number of SEVs have been developed in China, including VenusA-Valve (VENUSMEDTECH), J-Valve (JC Medical), VitaFlow (MicroPort), and TaurusOne (Peijia Medical). Thus far, some observational reports on populations with a very high prevalence of BAVs have demonstrated comparable early results between BAV and trileaflet patients with these devices.56–59 Additionally, a systematic review of Chinese TAVI patients suggested that the VenusA-Valve, which has the most evidence among Chinese aortic devices, may be associated with a lower rate of pacemaker implantation compared with the VitaFlow or TaurusOne valves.60 Future prospective studies of these devices will evaluate different sizing strategies (NCT04722796) and compare 1-year outcomes of TAVI vs surgery (NCT06597188) in the specific setting of BAV disease.

Overall, valve selection should be made on a case-by-case basis, considering general features shared with trileaflet valve patients (the presence of coronary artery disease, risk of pacemaker implantation, local availability, and experience), as well as specific BAV-related factors, such as the degree of annular and LVOT calcification (balancing the risks of annular rupture and residual leakage), a horizontal aortic root (larger angles are less favorable for Evolut SEVs, and either a BEV or an SEV with stabilizers should be considered), aortic annular size (smaller annuli seem to perform better with SEVs, in contrast to larger aortic annuli), the presence of a raphe (including its height and degree of calcification/fibrosis), and coronary eccentricity with the possibility of optimal commissural alignment (only available with SEVs in current clinical practice).

FUTURE PROSPECTS FOR BAV-TAVIGaps in knowledge

Several aspects of TAVI in patients with BAV remain unclear, hindering the development of robust decision-making algorithms for daily clinical practice.

Ascending aortic aortopathy and dilation are frequently found in BAV patients. However, whether these factors impact mid- and long-term clinical outcomes following TAVI is still unknown, as studies examining the progression of aortic diameters and complications such as dissection or rupture are lacking. This is particularly important in younger patients with longer life expectancies, as the need for subsequent ascending aorta surgical interventions after TAVI could be considered a failure of the Heart Team's decision-making.

It is well known that BAVs confer a higher risk of infective endocarditis compared with trileaflet valves, mainly due to tissue changes and altered flow patterns. However, the pathophysiology of infective endocarditis in BAV is not yet well defined. Therefore, whether a technique that crushes the native leaflets against the aortic wall rather than removing them increases the risk of future local infective events remains a hypothesis that should not be dismissed.

Valve durability is currently a critical consideration in TAVI, as the life-expectancy of patients treated with this approach increases yearly. Thus far, optimal bioprosthetic valve function has been observed at mid-term follow-up in patients with native trileaflet aortic valves.5 However, the higher annular eccentricity, differential calcium distribution, and heterogeneous THV compression observed in BAV patients raise concerns about the generalizability of these findings to bicuspid populations.20 Despite a recent analysis suggesting comparable rates of structural valve deterioration and bioprosthetic valve failure between tricuspid and bicuspid TAVI in Chinese patients at 5-years, more data should be gathered for other THV systems.61

Greater granularity on specific anatomical features is needed in BAV-TAVI registries. Types 0 and 1 Sievers BAVs differ significantly and should be considered as distinct scenarios for TAVI. Consensus on the presence or absence of a raphe and its anatomical configuration (flared or tapered) is crucial, and comparisons between specific THVs or against SAVR should systematically account for this factor.

Longer-term follow-up, a critical issue

As can be inferred from previous consensus,62 long-term reports in BAV patients are of utmost importance. A 10-year clinical and echocardiographic follow-up study of patients with BAV receiving new-generation Medtronic devices will provide information on valve durability and the risk of late valve-related complications (NCT03635424). Additionally, longer-term results from the BAV subgroups in the NOTION-2 trial (NCT02825134), with a minimum anticipated follow-up of 10-years, are also awaited.

A randomized TAVI vs SAVR trial in BAV, the best option for closing gaps

The study design would need to be more complex than those for trileaflet valve trials. Equipoise between the 2 techniques is not expected for all patients, as those with concomitant severe aortopathy or requiring a metallic prosthetic device or a Ross procedure would be excluded. Additionally, the ideal baseline anatomical characteristics must be clearly defined and balanced to ensure both representativeness and procedural feasibility, particularly for TAVI. Currently, dedicated reports outline potential study designs for a TAVI vs SAVR trial in BAV patients, emphasizing comprehensive long-term clinical and echocardiographic follow-up.63

CONCLUSIONS

The number of BAV patients referred for TAVI will significantly increase in the coming years. BAV has a wide range of anatomical variations, with factors such as annular dilation, morphology, calcium volume and distribution, and the presence and characteristics of the raphe influencing TAVI outcomes. Supra-annular sizing methods in raphe-type BAVs have emerged to improve sizing accuracy, and future studies are awaited before establishing these methods as the standard approach in BAV patients.

Contentious data exists on the comparison between BAV-TAVI and trileaflet valve TAVI, as well as between TAVI and SAVR in bicuspid patients. However, a trend toward a higher risk of residual PVL and stroke with TAVI seems plausible. Future randomized trials are needed to close this knowledge gap before extending the percutaneous TAVI approach to low-risk and younger patients with bicuspid anatomies.

FUNDING

No funding was received for the preparation of this manuscript.

STATEMENT ON THE USE OF ARTIFICIAL INTELLIGENCE

No artificial intelligence was used in the preparation of this manuscript.

AUTHORS’ CONTRIBUTIONS

Concept, design, and writing: A. Alperi, P. Avanzas. Literature research: A. Alperi, P. Avanzas. Interpretation, critical revision and final approval: all authors.

CONFLICTS OF INTEREST

P. Avanzas is associate editor of Revista Española de Cardiología; the journal's editorial procedure to ensure impartial processing of the manuscript has been followed. All other authors have nothing to disclose.

References
[1]
B. Iung, A. Vahanian.
Epidemiology of valvular heart disease in the adult.
Nat Rev Cardiol., (2011), 8 pp. 162-172
[2]
A. Vahanian, F. Beyersdorf, F. Praz, et al.
2021 ESC/EACTS Guidelines for the management of valvular heart disease.
Eur Heart J., (2022), 43 pp. 561-632
[3]
T. Bastante, D. Arzamendi, J. Martín-Moreiras, et al.
Spanish cardiac catheterization and coronary intervention registry. 33rd official report of the Interventional Cardiology Association of the Spanish Society of Cardiology (1990-2023).
Rev Esp Cardiol., (2024), 77 pp. 936-946
[4]
J.J. Popma, G. Michael Deeb, S.J. Yakubov, et al.
Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients.
New Engl J Med., (2019), 380 pp. 1706-1715
[5]
M.J. Mack, M.B. Leon, V.H. Thourani, et al.
Transcatheter Aortic-Valve Replacement in Low-Risk Patients at Five Years.
New Engl J Med., (2023), 389 pp. 1949-1960
[6]
A.S. Sillesen, O. Vøgg, C. Pihl, et al.
Prevalence of Bicuspid Aortic Valve and Associated Aortopathy in Newborns in Copenhagen, Denmark.
JAMA., (2021), 325 pp. 561-567
[7]
W.C. Roberts, J.M. Ko.
Frequency by decades of unicuspid, bicuspid, and tricuspid aortic valves in adults having isolated aortic valve replacement for aortic stenosis, with or without associated aortic regurgitation.
Circulation., (2005), 111 pp. 920-925
[8]
A. Alperi, P. Voisine, D. Kalavrouziotis, et al.
Aortic Valve Replacement in Low-Risk Patients With Severe Aortic Stenosis Outside Randomized Trials.
J Am Coll Cardiol., (2021), 77 pp. 111-123
[9]
F. Liu, Y.N. Yang, X. Xie, et al.
Prevalence of Congenital Heart Disease in Xinjiang Multi-Ethnic Region of China.
PLoS One., (2015), 10 pp. e0133961
[10]
R.R. Makkar, S.H. Yoon, M.B. Leon, et al.
Association between transcatheter aortic valve replacement for bicuspid vs tricuspid aortic stenosis and mortality or stroke.
JAMA., (2019), 321 pp. 2193-2202
[11]
K. Onishi, K. Mizutani, K. Fujita, et al.
Transcatheter Aortic Valve Implantation in Japanese Patients With Large Annulus: The OCEAN-TAVI Registry.
JACC: Asia., (2024), 4 pp. 686-694
[12]
Y.M. Li, T.Y. Xiong, K. Xu, et al.
Characteristics and outcomes following transcatheter aortic valve replacement in China: a report from China aortic valve transcatheter replacement registry (CARRY).
Chin Med J (Engl)., (2021), 134 pp. 2678-2684
[13]
C.H. Lee, T. Inohara, K. Hayashida, D.W. Park.
Transcatheter Aortic Valve Replacement in Asia: Present Status and Future Perspectives.
JACC: Asia., (2021), 1 pp. 279-293
[14]
H.H. Sievers, C. Schmidtke.
A classification system for the bicuspid aortic valve from 304 surgical specimens.
J Thorac Cardiovasc Surg., (2007), 133 pp. 1226-1233
[15]
H.I. Michelena, A. Della Corte, A. Evangelista, et al.
International consensus statement on nomenclature and classification of the congenital bicuspid aortic valve and its aortopathy, for clinical, surgical, interventional and research purposes.
Eur J Cardiothorac Surg., (2021), 60 pp. 448-476
[16]
Y. Watanabe, B. Chevalier, K. Hayashida, et al.
Comparison of multislice computed tomography findings between bicuspid and tricuspid aortic valves before and after transcatheter aortic valve implantation.
Catheter Cardiovasc Interv., (2015), 86 pp. 323-330
[17]
A. Buono, C. De Biase, T. Fabris, et al.
CharActeristics, sizing anD outcomes of stenotic, tapered, rapHe-type bicuspid aOrtic valves treated with trans-catheter device implantation: Insights the AD HOC registry.
Int J Cardiol., (2024), 417 pp. 132569
[18]
C. Juzga-Corrales, A. Ayerza-Casas, M. Figueras-Coll, et al.
Characteristics and outcomes of the Spanish registry for pediatric patients with bicuspid aortic valve (REVAB).
Rev Esp Cardiol., (2023), 76 pp. 961-969
[19]
N. Schamroth Pravda, Y. Plakht, A. Shiyovich, et al.
Characteristics of aortic root and vascular anatomy in bicuspid versus tricuspid aortic valve anatomy in patients referred for TAVR.
J Cardiovasc Comput Tomogr., (2024), 18 pp. 421-422
[20]
T. Nagasaka, V. Patel, A. Shechter, et al.
Impact of Balloon-Expandable TAVR Valve Deformation and Calcium Distribution on Outcomes in Bicuspid Aortic Valve.
JACC Cardiovasc Interv., (2024), 17 pp. 2023-2037
[21]
I.J. Amat-Santos, J. Sierra-Pallares, A. Redondo, S. Blasco-Turrión, J.P. Sánchez-Luna, J.C. González-Gutiérrez.
Fluid-dynamic impact of commissural alignment in transcatheter aortic valve implantation.
Rev Esp Cardiol., (2023), 76 pp. 566-568
[22]
S. Naito, J. Petersen, H. Reichenspurner, E. Girdauskas.
The impact of coronary anomalies on the outcome in aortic valve surgery: comparison of bicuspid aortic valve versus tricuspid aortic valve morphotype.
Interact Cardiovasc Thorac Surg., (2018), 26 pp. 617-622
[23]
F. Chen, T. Xiong, Y. Li, et al.
Risk of Coronary Obstruction During Redo-TAVR in Patients With Bicuspid Versus Tricuspid Aortic Valve Stenosis.
JACC Cardiovasc Interv., (2022), 15 pp. 712-724
[24]
H. Alkadhi, S. Leschka, P.T. Trindade, et al.
Cardiac CT for the differentiation of bicuspid and tricuspid aortic valves: Comparison with echocardiography and surgery.
Am J Roentgenology., (2010), 195 pp. 900-908
[25]
R.F. Ayad, P.A. Grayburn, J.M. Ko, G. Filardo, W.C. Roberts.
Accuracy of two-dimensional echocardiography in determining aortic valve structure in patients > 50 years of age having aortic valve replacement for aortic stenosis.
Am J Cardiol., (2011), 108 pp. 1589-1599
[26]
P. Blanke, J.R. Weir-McCall, S. Achenbach, et al.
Computed Tomography Imaging in the Context of Transcatheter Aortic Valve Implantation (TAVI)/Transcatheter Aortic Valve Replacement (TAVR): An Expert Consensus Document of the Society of Cardiovascular Computed Tomography.
JACC Cardiovasc Imaging., (2019), 12 pp. 1-24
[27]
D. Tchetche, C. De Biase, L. Van Gils, et al.
Bicuspid aortic valve anatomy and relationship with devices: The Bavard multicenter Registry: A European picture of contemporary multidetector computed tomography sizing for bicuspid valves.
Circ Cardiovasc Interv., (2019), 12 pp. e007107
[28]
G. Iannopollo, V. Romano, N. Buzzatti, et al.
Supra-annular sizing of transcatheter aortic valve prostheses in raphe-type bicuspid aortic valve disease: the LIRA method.
Int J Cardiol., (2020), 317 pp. 144-151
[29]
A.S. Petronio, M. Angelillis, O. De Backer, et al.
Bicuspid aortic valve sizing for transcatheter aortic valve implantation: Development and validation of an algorithm based on multi-slice computed tomography.
J Cardiovasc Comput Tomogr., (2020), 14 pp. 452-461
[30]
D. Blackman, D. Gabbieri, B.G. Del Blanco, et al.
Expert Consensus on Sizing and Positioning of SAPIEN 3/Ultra in Bicuspid Aortic Valves.
Cardiol Ther., (2021), 10 pp. 277-288
[31]
A. Alperi, P. Avanzas.
TAVR in tapered raphe-type stenotic bicuspid aortic valves: excellent results in challenging anatomies.
Int J Cardiol., (2025), 419 pp. 132656
[32]
X. Wang, O. De Backer, G. Bieliauskas, et al.
Cusp Symmetry and Coronary Ostial Eccentricity and its Impact on Coronary Access Following TAVR.
JACC Cardiovasc Interv., (2022), 15 pp. 123-134
[33]
F. Chen, Y. Feng, M. Chen.
Minimizing Neocommissural Overlap With Coronary Ostia During TAVR in Bicuspid Versus Tricuspid Aortic Stenosis.
JACC Cardiovasc Interv., (2022), 15 pp. 681-683
[34]
C. Montalto, A. Sticchi, G. Crimi, et al.
Outcomes After Transcatheter Aortic Valve Replacement in Bicuspid Versus Tricuspid Anatomy: A Systematic Review and Meta-Analysis.
JACC Cardiovasc Interv., (2021), 14 pp. 2144-2155
[35]
S.H. Yoon, S. Bleiziffer, O. De Backer, et al.
Outcomes in Transcatheter Aortic Valve Replacement for Bicuspid Versus Tricuspid Aortic Valve Stenosis.
J Am Coll Cardiol., (2017), 69 pp. 2579-2589
[36]
A. Mentias, M.V. Sarrazin, M.Y. Desai, et al.
Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Stenosis.
J Am Coll Cardiol., (2020), 75 pp. 2518-2519
[37]
Y. Sanaiha, J.E. Hadaya, Z. Tran, R.J. Shemin, P. Benharash.
Transcatheter and Surgical Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Stenosis.
Ann Thorac Surg., (2023), 115 pp. 611-618
[38]
P.S. Giannaris, V.S. Sehgal, B. Tejada, et al.
Transcatheter versus surgical valve replacement in patients with bicuspid aortic valves: an updated meta-analysis.
Br J Cardiol., (2024), 31 pp. 007
[39]
A. Elbadawi, M. Saad, I.Y. Elgendy, et al.
Temporal Trends and Outcomes of Transcatheter Versus Surgical Aortic Valve Replacement for Bicuspid Aortic Valve Stenosis.
JACC Cardiovasc Interv., (2019), 12 pp. 1811-1822
[40]
A. Husso, J. Airaksinen, T. Juvonen, et al.
Transcatheter and surgical aortic valve replacement in patients with bicuspid aortic valve.
Clin Res Cardiol., (2021), 110 pp. 429-439
[41]
M. Majmundar, A. Kumar, R. Doshi, et al.
Early outcomes of transcatheter versus surgical aortic valve implantation in patients with bicuspid aortic valve stenosis.
EuroIntervention., (2022), 18 pp. 23-32
[42]
Q. Chen, J. Malas, D. Megna, et al.
Bicuspid aortic stenosis: National three-year outcomes of transcatheter versus surgical aortic valve replacement among Medicare beneficiaries.
J Thoracic Cardiovasc Surg., (2024), 168 pp. 1035-1044.e17
[43]
T.H. Jørgensen, H.G.H. Thyregod, M. Savontaus, et al.
Transcatheter aortic valve implantation in low-risk tricuspid or bicuspid aortic stenosis: the NOTION-2 trial.
Eur Heart J., (2024), 45 pp. 3804-3814
[44]
I. Merdler, T. Rogers, B.C. Case, et al.
Two-year follow-up of transcatheter aortic valve replacement in low-risk patients with symptomatic severe bicuspid aortic valve stenosis.
Catheter Cardiovasc Interv., (2024), 104 pp. 583-590
[45]
F. Zahr, B. Ramlawi, M.J. Reardon, et al.
3-Year Outcomes From the Evolut Low Risk TAVR Bicuspid Study.
JACC Cardiovasc Interv., (2024), 17 pp. 1667-1675
[46]
D. Tchétché, F. Ziviello, C. De Biase, et al.
Transcatheter aortic valve implantation with the Evolut platform for bicuspid aortic valve stenosis: the international, multicentre, prospective BIVOLUTX registry.
EuroIntervention., (2023), 19 pp. 502-511
[47]
M.R. Williams, H. Jilaihawi, R. Makkar, et al.
The PARTNER 3 Bicuspid Registry for Transcatheter Aortic Valve Replacement in Low-Surgical-Risk Patients.
JACC Cardiovasc Interv., (2022), 15 pp. 523-532
[48]
H. Thiele, T. Kurz, H.J. Feistritzer, et al.
Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: The randomized SOLVE-TAVI trial.
Eur Heart J., (2020), 41 pp. 1890-1899
[49]
A. Mangieri, D. Tchetchè, W.K. Kim, et al.
Balloon Versus Self-Expandable Valve for the Treatment of Bicuspid Aortic Valve Stenosis: Insights from the BEAT International Collaborative Registrys.
Circ Cardiovasc Interv., (2020), 13 pp. 1-11
[50]
J. Rodés-Cabau, A. Alperi.
Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis: Does Valve Type Make a Differences?.
Circ Cardiovasc Interv., (2020), 13 pp. 120-122
[51]
E. Moscarella, A. Mangieri, F. Giannini, et al.
Annular size and interaction with trans-catheter aortic valves for treatment of severe bicuspid aortic valve stenosis: Insights from the BEAT registry.
Int J Cardiol., (2022), 349 pp. 31-38
[52]
A. Mangieri, A. Chieffo, W.K. Kim, et al.
Transcatheter aortic valve implantation using the ACURATE neo in bicuspid and tricuspid aortic valve stenosis: a propensity-matched analysis of a European experience.
EuroIntervention., (2018), 14 pp. e1269-e1275
[53]
I.J. Amat-Santos, M. García-Gómez, F. de Marco, et al.
Latest-iteration balloon- and self-expandable transcatheter valves for severe bicuspid aortic stenosis: the TRITON study.
Rev Esp Cardiol., (2023), 76 pp. 872-880
[54]
P. Jimenez-Quevedo, C. Espejo-Paeres, B. Hennessey.
Bicuspid aortic valve: one of the last remaining challenges for the percutaneous treatment of aortic valve disease.
Rev Esp Cardiol., (2023), 76 pp. 843-844
[55]
V. Bajoras, M. Dabrowski, G. Davidavicius, et al.
Three-Year Clinical and Hemodynamic Evaluation of the Hydra Self-Expanding Transcatheter Aortic Valve in Patients With Severe Aortic Stenosis.
Catheter Cardiovasc Interv., (2025), 105 pp. 292-300
[56]
D. Zhou, W. Pan, J. Wang, et al.
VitaFlowTM transcatheter valve system in the treatment of severe aortic stenosis: One-year results of a multicenter study.
Catheter Cardiovasc Interv., (2020), 95 pp. 332-338
[57]
Y.B. Liao, Z.G. Zhao, X. Wei, et al.
Transcatheter aortic valve implantation with the self-expandable venus A-Valve and CoreValve devices: Preliminary Experiences in China.
Catheter Cardiovasc Interv., (2017), 89 pp. 528-533
[58]
B. Fu, Q. Chen, F. Zhao, et al.
Efficacy and safety of transcatheter aortic valve implantation in patients with severe bicuspid aortic stenosis.
Ann Transl Med., (2020), 8
[59]
M. Wang, G. Song, M. Chen, et al.
Twelve-month outcomes of the TaurusOne valve for transcatheter aortic valve implantation in patients with severe aortic stenosis.
EuroIntervention., (2022), 17 pp. 1070-1076
[60]
L. Wei, B. Wang, Y. Yang, et al.
Transcatheter aortic valve replacement in China – a review of the available evidence.
Asia Intervention., (2024), 10 pp. 110-118
[61]
H. Li, De, W.Y. Li, J.L. Li, et al.
Long-Term Durability of Transcatheter Aortic Valve Prostheses in Patients With Bicuspid Versus Tricuspid Aortic Valve.
J Am Heart Assoc., (2024), 13 pp. e035772
[62]
T.Y. Xiong, W. Ali, Ben, Y. Feng, et al.
Transcatheter aortic valve implantation in patients with bicuspid valve morphology: a roadmap towards standardization.
Nat Rev Cardiol., (2023), 20 pp. 52-67
[63]
P. Nuyens, O. De Backer, J. Sathananthan, et al.
TAVR in Bicuspid Aortic Stenosis: Current Evidence and Proposal for a Randomized Controlled Trial Design.
JACC Cardiovasc Interv., (2023), 16 pp. 1682-1687
Copyright © 2025. Sociedad Española de Cardiología