Publish in this journal
Journal Information
Vol. 58. Issue 11.
Pages 1349-1350 (November 2005)
Share
Share
Download PDF
More article options
Vol. 58. Issue 11.
Pages 1349-1350 (November 2005)
DOI: 10.1016/S1885-5857(06)60422-2
Full text access
Complete Replacement of the Aorta in Marfan Disease. Follow-up using Vascular Magnetic Resonance Imaging
Sustitución completa de aorta en la enfermedad de Marfan. Control con angiorresonancia
Visits
5716
Mónica Fernández-Vallsa, Elena Gallardob, J Francisco Nistalc
a Servicio de Cardiología, Hospital Universitario Marqués de Valdecilla, Santander, Spain.
b Servicio de Radiodiagnóstico, Hospital Universitario Marqués de Valdecilla, Santander, Spain.
c Servicio de Cirugía Cardiovascular, Hospital Universitario Marqués de Valdecilla, Santander, Spain.
This item has received
5716
Visits
Article information
Full Text
Download PDF
Statistics
Figures (3)
Show moreShow less
Full Text

A 39-year-old man with no known cardiovascular risk factors was hospitalized for chest pain radiating to the side. Type A aortic dissection was diagnosed by transthoracic echocardiography and computed tomography (CT). Urgent surgery was performed, in which the ascending aorta was replaced with a valved tube graft (Bentall-Bono procedure). The patient had a phenotype typical of Marfan disease: height of 190 cm, long limbs, scoliosis and dural ectasia.

Postoperative follow-up included yearly imaging studies with transthoracic echocardiography and magnetic resonance angiography of the aorta. Two years later, after the aorta had reached a diameter of 59 mm in the curve distal to the origin of the supra-aortic trunks (Figure 1), a second operation, consisting of an elephant trunk technique (Figure 2) with on-pump circulation and retrograde cerebral perfusion was performed to repair the arch. The patient was thus prepared for the third and last operation, performed three months later and involving replacement of the remaining descending aorta up to the iliac bifurcation. In this way, the entire thoracoabdominal aorta was replaced with a Vascutek tube graft, as is seen in the final magnetic resonance angiography image (Figure 3).

Figure 1.

Figure 2.

Figure 3.

Total thoracoabdominal aortic substitution was performed in our patient in three surgical stages, thereby altering the dismal natural history of these patients, characterized by high mortality at an early age.

Idiomas
Revista Española de Cardiología (English Edition)

Subscribe to our newsletter

Article options
Tools
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

es en
Política de cookies Cookies policy
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación. Si continua navegando, consideramos que acepta su uso. Puede cambiar la configuración u obtener más información aquí. To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here.