Publish in this journal
Journal Information
Vol. 67. Issue 12.
Pages 1055 (December 2014)
Share
Share
Download PDF
More article options
Vol. 67. Issue 12.
Pages 1055 (December 2014)
Image in cardiology
DOI: 10.1016/j.rec.2014.02.017
Full text access
Coronary Aneurysm Closure With Pericardial Covered Stent Evaluated With Optical Coherence Tomography
Cierre de aneurisma coronario con stent de pericardio evaluado con tomografía de coherencia óptica
Visits
...
Carlos Ortiz
Corresponding author
ortiz.bautista.carlos@gmail.com

Corresponding author:
, Ana Serrador, José Alberto San Román
Servicio de Cardiología, Hospital Clínico Universitario de Valladolid, Instituto de Ciencias del Corazón (ICICOR), Valladolid, Spain
Article information
Full Text
Download PDF
Statistics
Figures (2)
Full Text

A 62-year-old man with personal history of arterial hypertension and smoking was admitted to our hospital with ST elevation myocardial infarction. Intravenous fibrinolytic therapy was given by emergency services during hospital transfer, which was effective. Routine coronary angiography showed moderate lesion on the proximal left anterior descending, proximal coronary aneurysm (Figure 1A, asterisk) and significant lesions at mid segment of circumflex (white arrow) and proximal segment of the second marginal (arrowhead). The case was discussed with the heart team and the decision was made to perform percutaneous coronary intervention.

Figure 1
(0.09MB).

Balloon predilation was performed and drug-eluting stent was implanted in second marginal followed by direct drug-eluting stent implantation at mid segment of circumflex, fitting the proximal stent to distal origin of aneurysm. A 3.5×18mm, pericardial, covered stent (Aneugraft, ITGI Medical Ltd., Israel) was implanted at circumflex aneurysm, overlapped to the distal drug-eluting stent with good final result (Figure 1B). Several optical coherence tomography pullbacks were conducted in order to confirm correct implantation of pericardial covered stent (Figure 2A, asterisk) and correct overlapping with distal drug-eluting stent (Figure 2B, white arrow). Patient was discharged on dual antiplatelet therapy with aspirin and clopidogrel for 1 year.

Figure 2
(0.13MB).

Although initially designed for vein graft angioplasty, pericardial covered stents have been used to treat other problems in interventional cardiology, such as coronary aneurysm, with limited experience. We present here what is, to the best of our knowledge, the first case to use optical coherence tomography to evaluate the final result of pericardial covered stenting in coronary aneurysm.

Copyright © 2014. Sociedad Española de Cardiología