Publish in this journal
Journal Information
Vol. 76. Issue 3.
Pages 211 (March 2023)
Visits
Not available
Vol. 76. Issue 3.
Pages 211 (March 2023)
Image in cardiology
Full text access
Leadless pacemaker implantation in Eisenmenger syndrome
Marcapasos sin cables en el síndrome de Eisenmenger
Visits
259
José Luis Martínez-Sandea,b,c,d,
Corresponding author
luismartinezsande@gmail.com

Corresponding autor.
, Carlos Minguito-Carazoa,b, Laila González-Melchora,b,c,d
a Unidad de Arritmias y Electrofisiología Cardiaca, Servicio de Cardiología, Hospital Clínico Universitario de Santiago de Compostela, Santiago de Compostela, A Coruña, Spain
b Unidad Coronaria, Servicio de Cardiología, Hospital Clínico Universitario de Santiago de Compostela, Santiago de Compostela, A Coruña, Spain
c Instituto para el Desarrollo e Integración de la Salud (IDIS), Santiago de Compostela, A Coruña, Spain
d Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain
This item has received
Article information
Full Text
Download PDF
Statistics
Figures (2)
Additional material (3)
Full Text

Transvenous pacemakers are contraindicated in Eisenmenger syndrome due to the high risk of paradoxical embolism. Leadless pacemakers are preferred because of their tendency to become encapsulated and the absence of leads in low-pressure chambers (right atrium [RA]).

We present the case of a 71-year-old man admitted for complete atrioventricular block. The patient had uncorrected congenital heart disease with a double-chambered right ventricle (RV) and a perimembranous interventricular septal defect with bidirectional flow, pulmonary hypertension in the context of Eisenmenger syndrome, and moderate chronic pericardial effusion (figure 1A, arrow; LA, left atrium; LV, left ventricle). Considering the patient's history of documented paroxysmal atrial fibrillation, it was decided to implant a leadless pacemaker.

Figure 1
(0.09MB).

The pacemaker was deployed in the right ventricular outflow tract (RVOT) with the aid of intracardiac echocardiography-fluoroscopy fusion imaging (Cartosound-Univu electroanatomic navigation modules; Biosense Webster, USA). This approach circumvented the need to access the left cavities through the ventricular septal defect, enabled exclusion of the hypertrabeculated part of the RV, and guided the selection of an optimal implantation site.

Excellent pacing and sensing parameters were observed following the initial delivery of the pacemaker into the RVOT (figure 1B, Cvideos 1 and 2 of the supplementary material).

The final position of the device is shown in Figure 2A, B (echocardiogram and chest radiograph, respectively) and video 3 of the supplementary material. Informed consent was obtained from the patient for publication of case details.

Figure 2
(0.1MB).

Leadless pacemakers could be the best option for patients with Eisenmenger syndrome due to their lower thrombogenicity. Hybrid imaging techniques potentially improve the safety of pacemaker implantation.

Funding

None

Authors’ Contributions

All the authors wrote, reviewed, and approved the manuscript.

Conflicts of Interest

J.L. Martínez-Sande has received consultancy fees from Medtronic. The other authors declare that they have no conflicts of interest.

APPENDIX. SUPPLEMENTARY DATA

Supplementary data associated with this article can be found in the online version, at https://doi.org/10.1016/j.rec.2022.08.010

Appendix B
SUPPLEMENTARY MATERIAL

(1.98MB)
(0.43MB)
(0.37MB)

Copyright © 2022. Sociedad Española de Cardiología
Idiomas
Revista Española de Cardiología (English Edition)

Subscribe to our newsletter

View newsletter history
Article options
Tools
Supplemental materials
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?