New Catheter, Wide Angle Imaging, 3D Intracardiac Echocardiography
Nuevo catéter, ángulo largo, de ecocardiografía intracardiaca 3D
Visits
820
José Ribeiro
Corresponding author
cardiogaia@gmail.com

Corresponding author:
, Pedro Braga, Vasco Gama
Cardiology Department, Centro Hospitalar Gaia/Espinho, Vila Nova de Gaia, Portugal
This item has received
820
Visits
Article information
Full Text
Download PDF
Statistics
Figures (2)
Additional material (2)
Full Text

During the last few years, the continuous development of intracardiac echocardiography (ICE) has allowed it to play an important role in guiding several interventions in structural heart disease, without the need for general anesthesia. However, the currently available 3-dimensional ICE catheter has a short elevation angle (maximum 90° x 24°), which limits its ability to view complete cardiac structures or devices.

We report the first European clinical use of volume ICE with an enlarged opening angle to guide left atrial appendage (LAA) closure. Interfaced with the ACUSON SC200 ultrasound system (Siemens Healthineers, Erlangen, Germany), the ACUSON AcuNav Volume ICE technology is a 12.5-Fr catheter, capable of obtaining a volume of 90° x 50° with a volume frame rate of 16 volumes per second.

Figure 1A was acquired with the catheter placed in the right atrium and shows the interatrial septum and its relationship with the aortic valve and coronary sinus and can be used to guide the interatrial puncture. Figure 1B was acquired from the left atrium and shows the entire LAA opening. Figure 1C depicts the LAA pulsed-wave flow recording. The LAA multiplanar reconstruction with the circle measurement tool can be viewed in Figure 1D, which also shows the circumflex artery (Cx). Figure 1E was acquired at the end of the procedure and shows the Amplatzer device correctly implanted in LAA in 2-dimensional and 3-dimensional views (Video 1 of the supplementary material). Finally, Figures 2A and 2B show all the leaflets of mitral and tricuspid valves (Video 2 of the supplementary material).

(0.18MB).
(0.1MB).
Copyright © 2018. Sociedad Española de Cardiología
Idiomas
Revista Española de Cardiología (English Edition)

Subscribe to our newsletter

Article options
Tools
Supplemental materials
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

es en
Política de cookies Cookies policy
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación. Si continua navegando, consideramos que acepta su uso. Puede cambiar la configuración u obtener más información aquí. To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here.