Optical Coherence Tomography Imaging in Coronary Drug-Eluting Stenting
Tomografía de coherencia óptica en la evaluación de las endoprótesis coronarias con capacidad de liberación de fármacos
Visits
5114
Ulrich Gerckensa, Victor Y Lima, Eberhard Grubea
This item has received
5114
Visits
Article information
Full Text
Download PDF
Statistics
Figures (3)
Show moreShow less
Full Text

Optical coherence tomography (OCT) is a new intracoronary imaging modality providing images with a resolution 10 times higher than that provided by intravascular ultrasound (IVUS). As the near infra-red light waves used in OCT cannot penetrate blood, we create a blood-free field necessary for imaging by transient occlusion of the vessel proximal to the lesion with a special low pressure balloon catheter followed by saline flushing. The superior imaging capability may be helpful in assessing the efficacy and behaviour of various drug-eluting stents during follow-up. We present a series of OCT images demonstrating features that would be difficult to discern on IVUS. Figure 1 shows the primary implantation of a Cypher sirolimus-eluting stent for in-stent restenosis in the left anterior descending artery (LAD); post-stenting, a tongue of neointimal tissue protruding between the stent struts (single arrow) is clearly seen. Figure 2 shows a 10-month follow-up case of Cypher stenting for a de novo LAD lesion, where a thin layer of neointimal tissue covering the stent struts can be seen. A slight "blown-out" appearance is also demonstrated here (multiple arrows indicating where the vessel wall is slightly concave); we believe this may be an artifact, often seen where the neointimal layer is thin, due to intraluminal pressurization from flushing of a balloon-occluded vessel. Figure 3 shows a case of circumflex artery in-stent restenosis 6 months after implantation of a Taxus paclitaxel-eluting stent; the concentric layer of thick neointimal hyperplasia is well visualized and can be accurately measured.

Figure 1.

Figure 2.

Figure 3.

Idiomas
Revista Española de Cardiología (English Edition)

Subscribe to our newsletter

Article options
Tools
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

es en
Política de cookies Cookies policy
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación. Si continua navegando, consideramos que acepta su uso. Puede cambiar la configuración u obtener más información aquí. To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here.