Symptomatic Late-acquired Coronary Dissection: Value of Intracoronary Images
Disección coronaria diferida sintomática: valor de la imagen intracoronaria
Visits
7246
Roberto del Castillo Medina
Corresponding author
rcastillo@fhalcorcon.es

Corresponding author:
, Lorenzo Hernando Marrupe, Javier Botas Rodríguez
Servicio de Cardiología, Hospital Universitario Fundación Alcorcón, Alcorcón, Madrid, Spain
This item has received
Article information
Full Text
Download PDF
Statistics
Figures (3)
Show moreShow less
Full Text

An 80-year-old man, who was hypertensive, diabetic, and a smoker, was referred to our center due to unstable angina. He had been admitted to another center 3 months previously for a non-Q-wave infarction where he underwent percutaneous revascularization of the anterior descending artery and proximal and middle portions of the right coronary artery using 3 standard stents.

Right coronary angiography showed a double lumen image in the middle third, coinciding with the artery portion treated previously, providing an angiographic image of apparent dissection (Figs. 1A-E, arrows). Intracoronary ultrasound confirmed the presence of various phenomena (Fig. 2): a) incorrect positioning and underexpansion of both distal stents (arrows); b) contrast transfer to a parallel space with a semicircular cross-section (asterisk); and c) persistence of the intima-medial interface in the vessel wall (arrow tip) and the presence of an intimal/neointimal layer covering the outer surface of the stent.

Figure 1
(0.09MB).
Figure 2
(0.09MB).

The potential causes of these findings could have been the following: a) unsuitable selection of stent size in an artery with spasm and thrombus; b) partially subintimal trajectory of the stents; and c) dissection/intramural hematoma after stent implantation and late double lumen development due to reabsorption of the thrombotic content, or a combination of these causes.

An angioplasty was performed on the stent with appropriately-sized high pressure non-compliant balloons to position the stents properly and obliterate the adjacent lumen (Figs. 3A–E). The intracoronary ultrasound made a decisive contribution to the choice of materials and helped optimize the result.

Figure 3
(0.09MB).

Copyright © 2012. Sociedad Española de Cardiología
Idiomas
Revista Española de Cardiología (English Edition)

Subscribe to our newsletter

View newsletter history
Article options
Tools
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?