Three-dimensional Model for Percutaneous Closure of an Iatrogenic Fistula
Modelo tridimensional para cierre percutáneo de fístula iatrogénica
Visits
...
Jorge Sanz Sáncheza,
Corresponding author
sjorge4@gmx.com

Corresponding author:
, Francisco Ten Morroa,b, Elena Sánchez Lacuestaa,b
a Sección de Hemodinámica y Cardiología Intervencionista, Servicio de Cardiología, Hospital Universitari i Politècnic La Fe, Valencia, Spain
b Unidad de Tratamiento Percutáneo de la Válvula Aórtica, Hospital Universitari i Politècnic La Fe, Valencia, Spain
This item has received
...
Visits
(Daily data update)
Article information
Full Text
Download PDF
Statistics
Figures (2)
Full Text

Full English text available from: www.revespcardiol.org/en

A 74-year-old woman who had undergone mechanical mitral valve replacement and tricuspid annuloplasty 2 years previously was admitted with decompensated heart failure.

Echocardiography revealed a 4 x 3mm fistula between the aorta and right atrium with high velocity flow between the anterior leaflet and the annuloplasty suture zone (Figure 1A).

(0.2MB).

Because the patient was symptomatic and had a high surgical risk, a percutaneous approach was used. Before the procedure, a 3-dimensional model was constructed (Figure 2), which allowed simulation of closure with different devices. The 3×6mm Amplatzer Duct Occluder IIwas chosen as this device achieved the most complete closure of the defect.

(0.07MB).

Via the left femoral artery, the fistula was cannulated from the aorta (Figure 1B, white arrow) with a hydrophilic guidewire (Figure 1B, blue arrow) and the aid of a 4-Fr multipurpose diagnostic catheter. To establish the arteriovenous circuit, the guidewire was captured with a snare catheter in the right atrium (Figure 1C) and externalized via the right femoral vein. Finally, the device previously tested in the model was deployed from the right femoral vein and complete closure was achieved with no residual flow.

Aorto-right atrial fistulae are an uncommon complication following cardiac surgery. Closure is recommended if patients are symptomatic, and the percutaneous approach is a therapeutic option. The creation of a 3-dimensional model prior to the procedure helps in planning and selecting the best closure device.

Copyright © 2017. Sociedad Española de Cardiología
Idiomas
Revista Española de Cardiología (English Edition)

Subscribe to our newsletter

Article options
Tools
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

es en
Política de cookies Cookies policy
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación. Si continua navegando, consideramos que acepta su uso. Puede cambiar la configuración u obtener más información aquí. To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here.